Notice: Function id was called incorrectly. Product properties should not be accessed directly. Backtrace: require('wp-blog-header.php'), require_once('wp-includes/template-loader.php'), include('/plugins/woocommerce/templates/single-product.php'), wc_get_template_part, load_template, require('/plugins/woocommerce/templates/content-single-product.php'), do_action('woocommerce_after_single_product_summary'), WP_Hook->do_action, WP_Hook->apply_filters, woocommerce_output_product_data_tabs, wc_get_template, include('/plugins/woocommerce/templates/single-product/tabs/tabs.php'), woocommerce_product_description_tab, wc_get_template, include('/plugins/woocommerce/templates/single-product/tabs/description.php'), apply_filters('woocommerce_product_description_heading'), WP_Hook->apply_filters, WC_Tab_Manager->core_tab_heading, WC_Abstract_Legacy_Product->__get, wc_doing_it_wrong Please see Debugging in WordPress for more information. in /home/customer/www/hvacep.com/public_html/wp-includes/functions.php on line 5835
Product Description
Airtest TR3210-NO2 Nitrogen Dioxide Gas Transmitter
Airtest TR3210-NO2 Gas Transmitter : NO2 Transmitter, 4-20 mA: Wall mount, electrochemical nitrogen dioxide (NO2) trnsmitter, 4-20 mA loop powered, 3 year lif, 0-10 ppm range. Replacible sensor element. Mounts on single gang electrical box (included). TR3210-NO2-LON: NO2 Transmitter, LonWorks: Wall mount electrochemical nitrogen dioxide (NO2) transmitter, 3 year life, LonWorks communicating (% of range), 0-200 ppm, 18-24VDC power input. Replacable sensor element. Mounts on single gang electrical box (included).
ALL AIRTEST GAS SENSORS ARE PRECALIBRATED AT THE FACTORY. NO ADDITIONAL CALIBRATION IS REQUIRED.
Applications
- water treatment. pools, food processing
- Control of diesel fumes in: indoor parking, bus garages, service garages, arenas, fire stations, loading docks, warehouses
- BACnet® version available soon
- Use with digital building control systems / VFD control / LonWorks®
Key Features
- High accuracy electrochemical sensor in rugged enclosure
- NO2 specific (negligible interference from humidity and other gases)
- Loop powered, linear output
- 18 month operating life
- Plug-in replaceable sensor element available
- CSA certified
- Now also available with LonWorks®communication capability.
Model TR3210-NO2 Technical Data:
- Temp Range: -40 to 140°F (-40 to 60°C)
- Output: 4-20 mA (loop powered)
- Power: 12-30 VDC
- Measures: 0-10 ppm
- Calibration: 1 year recommended
- Same performance as TR3210-NO2 above.
- LonWorks® Network Variabies: nviRequest, nciMaxStsSendT, nvoStatus
- LonWorks® Sensor Variables: nvoSensorValue (% of range), nvoSensorInv, nciMiniDelta, nciSnsrSmplRate
Can be used with Model CT1000 Controller
- Note: When Used with the TR3210 controller it is not integrated with sensor. Must be ordered and installed separately.